Place of Origin: | Chengdu, China |
---|---|
Brand Name: | FHDT |
Certification: | IEC A1a.1 |
Model Number: | Optical and electrical hybrid cables for access network |
Minimum Order Quantity: | 500 Drums |
Price: | Negotiable |
Packaging Details: | No more than 4km/drum |
Delivery Time: | Depends on specific specifications and demand |
Payment Terms: | Usually T/T, other terms negotiable |
Supply Ability: | Depends on specific specifications and demand |
Loose Tube: | PBT Loose Tube | Filler: | Polypropylene |
---|---|---|---|
Strength Member: | Phosphating Steel Wire | Water Blocking Material: | Water Blocking Yarn/tape |
Fiber Count Per Tube: | G.652D-12 | Central Strength Member: | FRP |
Armor: | PE Coated Corrugated Steel Tape | Operation Temperature: | -40℃~+60℃ |
Storage Temperature: | -40℃~+60℃ | ||
Highlight: | G.652D-12 Hybrid Fiber Optic Cable,PBT Loose tube hybrid fiber cable,G.652D-12 hybrid fiber cable |
● Accurate process control ensuring good mechanical and temperature performances.
● Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment.
● Improving manageability of power and reducing coordination and maintenance of power supply.
● Reducing procurement costs and saving construction costs.
● Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station.
● Applicable to duct and aerial installations.
Fibre attributes | |||
Attribute | Detail | Value | Unit |
Mode field diameter | Wavelength | 1310 | nm |
Range of nominal values | 8.6-9.2 | μm | |
Tolerance | ± 0.4 | μm | |
Cladding diameter | Nominal | 125.0 | μm |
Tolerance | ± 0.7 | μm | |
Core concentricity error | Maximum | 0.6 | μm |
Cladding noncircularity | Maximum | 1.0 | % |
Cable cut-off wavelength | Maximum | 1260 | nm |
Macrobending loss | Radius | 30 | mm |
Number of turns | 100 | ||
Maximum at 1625 nm | 0.1 | dB | |
Proof stress | Minimum | 0.69 | GPa |
Chromatic dispersion parameter | λ0min | 1300 | nm |
λ0max | 1324 | nm | |
S0max | 0.092 | ps/(nm2 × km) | |
Cable attributes | |||
Attribute | Detail | Value | Unit |
Attenuation coefficient | Maximum at 1310 nm | 0.38 | dB/km |
Maximum at 1550 nm | 0.25 | dB/km | |
Maximum at 1625 nm | 0.38 | dB/km | |
PMD coefficient | M | 20 | cables |
Q | 0.01 | % | |
Maximum PMDQ | 0.20 | ps/ |
The standard structure of GDTS cable is shown in the following table, other structure and fiber count are also available according to customer requirements.
Item | Contents | Value | Remarks | |
12 | 24 | |||
Loose tube | Number | 1 | 2 | |
Outer diameter (mm) | 3.2 | 3.2 | PBT | |
Filler | Number | 1 | 0 | Polypropylene |
Fiber count per tube | G.652D | 12 | 12 | |
Power wire | Type | 2.5mm2 | ||
Conductor | Copper | Class 1:solid conductors | ||
Number | 2 | |||
Max. DC resistance of single conductor (20℃)(Ω/km) | 7.98 | |||
Central strength member | Material | FRP | ||
Diameter (mm) | 1.0 | |||
PE layer diameter (mm) | 1.6 | |||
Water Blocking Material | Material | Water blocking yarn | ||
Water blocking tape | ||||
Armor | Material | PE coated corrugated steel tape | ||
Outer sheath | Material | MDPE | ||
Color | Black | |||
Thickness (mm) | Nominal: 1.8 | |||
Cable diameter(mm) Approx. | 13.4 | |||
Cable weight(kg/km) Approx. | 190 |
Main Mechanical and Environmental Performance
Item | Value |
Tensile performance(N) | 1500 |
Crush(N/100mm) | 1000 |
Operation temperature: | -40℃~+60℃ |
Installation temperature | -15℃~+60℃ |
Storage temperature | -40℃~+60℃ |
The standard delivery length of a cable is 2000m or 3000m with the tolerance 0~+20m. If special requests are made in the contract, the supplied cable length should conform to it.